Airfoil AH 79-K-135/20 B97 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

AH 79-K-135/20 B airfoil

AH 79-K-135/20 B is 13.5% thick at 40% chord, 3.0% camber at 40% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare AH 79-K-135/20 B with other airfoils

00.250.50.751 = chord
Shape of AH 79-K-135/20 B, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness13.49% at 40.2% chord
Max camber3.05% at 40.2% chord
Trailing-edge gap0.00%
Points in source file97
Best L/D (XFOIL, Ncrit 9)153.5 at 2.5°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

97 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00024.7 at 10.5°1.16 at 13°0.0315
100,00048.1 at 8.5°1.17 at 13.25°0.0223
150,00065.3 at 7.75°1.17 at 13.5°0.0163
200,00078.8 at 6.75°1.17 at 13.75°0.0135
500,000104.3 at 5.75°1.21 at 15°0.0082
1 million123.2 at 4.25°1.23 at 15.5°0.0059
2 million142.6 at 3°1.33 at 16°0.0042
5 million153.5 at 2.5°1.57 at 17° No clear stall0.0034
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00024.2 at 10°1.00 at 15°0.0278
100,00046.3 at 8°1.08 at 15°0.0195
150,00064.5 at 6.75°1.11 at 15.25°0.0153
200,00074.3 at 6.25°1.13 at 15.5°0.0127
500,00095.0 at 4.5°1.18 at 16°0.0076
1 million111.3 at 3.5°1.27 at 15.5°0.0054
2 million121.3 at 2.75°1.42 at 17°0.0044
5 million119.8 at 2.5°1.62 at 18.75° No clear stall0.0046
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources