Airfoil CH10 (smoothed)79 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3Wind tunnel: UIUC LSAT, 1 test

CH10 (smoothed) airfoil

CH10 (smoothed) is 12.8% thick at 31% chord, 10.2% camber at 49% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million. Wind-tunnel measurements from the UIUC Low-Speed Airfoil Tests.

Compare CH10 (smoothed) with other airfoils

00.250.50.751 = chord
Shape of CH10 (smoothed), drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness12.84% at 30.6% chord
Max camber10.20% at 49.2% chord
Trailing-edge gap0.01%
Points in source file79
Best L/D (XFOIL, Ncrit 9)258.8 at 5°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

79 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil + wind tunnel

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,0006.2 at 6.5°≥ 1.33 at 18.5° Stall not computed0.1054
100,000 Doubtful10.9 at 4.5°≥ 1.48 at 16.75° Stall not computed0.0787
150,000 Unreliable25.0 at -0.5°≥ 0.91 at -0.5° Stall not computed0.0365
200,00073.2 at 7.25°2.06 at 10.75°0.0203
500,000135.4 at 4.25°2.05 at 11°0.0111
1 million175.3 at 2.75°2.06 at 10.5°0.0087
2 million216.0 at 4°2.05 at 9.75°0.0073
5 million258.8 at 5°2.02 at 9°0.0060
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,000 Doubtful22.1 at 17.25°2.20 at 17.25°0.0662
100,000 Unreliable37.3 at 1.25°≥ 1.13 at 1.25° Stall not computed0.0299
150,00069.1 at 3°1.87 at 12.75°0.0195
200,00086.3 at 3.25°1.94 at 11.75°0.0164
500,000132.4 at 3.25°1.98 at 10.25°0.0112
1 million164.0 at 3.75°1.98 at 9.25°0.0090
2 million192.5 at 4.75°1.97 at 8.75°0.0076
5 million216.0 at 3°1.98 at 18° No clear stall0.0063
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 100,000, Ncrit 5: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 150,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°.
  • Doubtful Use with care; see the reasons. Re 50,000, Ncrit 5: XFOIL's lift jumped far from the curve at single angles and straight back; those points were removed; Re 100,000, Ncrit 9: XFOIL converged at fewer than three quarters of the angles from −5° to 15°, XFOIL's lift jumped far from the curve at single angles and straight back; those points were removed.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 200,000, 500,000, 1 million, 2 million, 5 million (Ncrit 9); Re 50,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 5).

Wind-tunnel measurements

Wind-tunnel data: UIUC Low-Speed Airfoil Tests (LSAT). Produced under the UIUC Low-Speed Airfoil Tests (LSAT) program by Prof. Michael Selig and the UIUC Applied Aerodynamics Group, University of Illinois at Urbana-Champaign (UIUC Applied Aerodynamics Group). Free to use and share under the GNU General Public License; licence, copyright notice and the LSAT Manifesto. Never charged for.

  • Volume 1: M. S. Selig, J. J. Guglielmo, A. P. Broeren and P. Giguère, Summary of Low-Speed Airfoil Data, Volume 1, SoarTech Publications, 1995.
How the measurements are shown

CH10 (smoothed) was tested in the UIUC low-turbulence wind tunnel: 1 test with 7 runs. In the charts above the measurements are markers, the XFOIL predictions lines. Lift and moment come from the force balance, drag from a wake rake in separate runs at their own angles, so the two kinds of run are shown separately and never combined. Each run is shown at its own measured Reynolds number; nothing is interpolated.

All 1 tests and all Reynolds numbers
  • Volume 1, CH 10-48-13, tripped (plain trip @ x/c = 40% (h/c = 0.2%; w/c = 0.9%)): lift curves at Re 99,400, 126,700, 151,800, 176,500, 201,200; drag polars at Re 199,600, 202,500; no moment data.

Reliability and data quality

About these predictions
  • Lines are computer predictions, markers are measurements. The polar lines and the performance table are XFOIL predictions (dashed lines: NeuralFoil estimates). XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. The markers are wind-tunnel measurements from the UIUC Low-Speed Airfoil Tests; see Wind-tunnel measurements below.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources