Airfoil E193 (10.22%)61 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3Wind tunnel: UIUC LSAT, 1 test

E193 (10.22%) airfoil

E193 (10.22%) is 10.2% thick at 31% chord, 3.6% camber at 40% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million. Wind-tunnel measurements from the UIUC Low-Speed Airfoil Tests.

Compare E193 (10.22%) with other airfoils

00.250.50.751 = chord
Shape of E193 (10.22%), drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness10.22% at 31.0% chord
Max camber3.57% at 40.0% chord
Trailing-edge gap0.00%
Points in source file61
Best L/D (XFOIL, Ncrit 9)175.9 at 3.5°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

61 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil + wind tunnel

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Suspicious results. Suspicious drag at Re 100,000 (Ncrit 9): The minimum drag is lower than even a perfectly smooth flat plate with fully laminar flow could achieve, so XFOIL's result can't be right. These polars are still shown, marked, so you can judge them yourself, but don't rely on them.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00035.7 at 8.75°1.27 at 11.5°0.0252
100,000 Unreliable Suspicious drag58.6 at 8°1.28 at 12.25°0.0066
150,00072.3 at 7.25°1.27 at 12.5°0.0110
200,00082.2 at 7°1.28 at 13°0.0095
500,000113.4 at 5.75°1.31 at 14°0.0066
1 million137.3 at 4.75°1.34 at 14.25°0.0052
2 million159.1 at 4°1.42 at 15°0.0043
5 million175.9 at 3.5°1.64 at 16.5°0.0040
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00035.9 at 8.25°1.12 at 9°0.0193
100,00058.9 at 7.25°1.19 at 13.75°0.0127
150,00071.5 at 6.5°1.22 at 14°0.0106
200,00080.3 at 6.25°1.24 at 14.25°0.0094
500,000106.9 at 4.75°1.31 at 14.25°0.0068
1 million125.3 at 4°1.40 at 14.5°0.0056
2 million140.6 at 3.5°1.53 at 16.5°0.0051
5 million122.6 at 3°1.70 at 17.5° No clear stall0.0053
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 100,000, Ncrit 9: Suspicious drag.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million, 5 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 5).

Wind-tunnel measurements

Wind-tunnel data: UIUC Low-Speed Airfoil Tests (LSAT). Produced under the UIUC Low-Speed Airfoil Tests (LSAT) program by Prof. Michael Selig and the UIUC Applied Aerodynamics Group, University of Illinois at Urbana-Champaign (UIUC Applied Aerodynamics Group). Free to use and share under the GNU General Public License; licence, copyright notice and the LSAT Manifesto. Never charged for.

  • SoarTech 8: M. S. Selig et al., Airfoils at Low Speeds, SoarTech 8, SoarTech Publications, 1989 (data disk).
How the measurements are shown

E193 (10.22%) was tested in the UIUC low-turbulence wind tunnel: 1 test with 4 runs. In the charts above the measurements are markers, the XFOIL predictions lines. Lift and moment come from the force balance, drag from a wake rake in separate runs at their own angles, so the two kinds of run are shown separately and never combined. Each run is shown at its own measured Reynolds number; nothing is interpolated.

Wind tunnel vs XFOIL table: clean models only, where the measured Reynolds number is within 5% of one XFOIL was computed at. XFOIL: Ncrit 9. “≥” means the value may be higher (the measured lift run or the XFOIL polar ended before lift fell). Highest and lowest of the measured points, as printed in the source; no curve is fitted.

Wind tunnel vs XFOIL

ReMax lift, measured / XFOILMin drag, measured / XFOIL
100,000SoarTech 8, E193; measured Re: drag 97,500– / 1.280no lift run at this Re0.0134 / 0.0066measured at CL 0.22
200,000SoarTech 8, E193; measured Re: drag 204,200– / 1.278no lift run at this Re0.0100 / 0.0095measured at CL 0.30
All 1 tests and all Reynolds numbers
  • SoarTech 8, E193, clean: drag polars at Re 60,200, 97,500, 204,200, 303,100; no moment data.

Reliability and data quality

About these predictions
  • Lines are computer predictions, markers are measurements. The polar lines and the performance table are XFOIL predictions (dashed lines: NeuralFoil estimates). XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. The markers are wind-tunnel measurements from the UIUC Low-Speed Airfoil Tests; see Wind-tunnel measurements below.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources