Airfoil EPPLER 580 (e580)61 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

EPPLER 580 airfoil (e580)

EPPLER 580 is 16.1% thick at 35% chord, 4.1% camber at 61% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare EPPLER 580 with other airfoils

00.250.50.751 = chord
Shape of EPPLER 580, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness16.08% at 35.4% chord
Max camber4.08% at 61.1% chord
Trailing-edge gap0.00%
Points in source file61
Best L/D (XFOIL, Ncrit 9)174.2 at 4°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

61 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,0007.4 at 7.25°≥ 0.99 at 14.25° Stall not computed0.0390
100,00052.1 at 10°1.56 at 11.25°0.0268
150,00066.5 at 9°1.55 at 11.5°0.0172
200,00076.1 at 8°1.54 at 11.75°0.0129
500,000107.3 at 6.25°1.57 at 13°0.0080
1 million131.4 at 5.5°1.61 at 15.25°0.0065
2 million153.0 at 4.75°1.69 at 16.75°0.0056
5 million174.2 at 4°1.84 at 17.75° No clear stall0.0049
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00024.4 at 9°1.32 at 13.75°0.0301
100,00054.4 at 7.25°1.45 at 12°0.0179
150,00067.5 at 7°1.48 at 12°0.0138
200,00076.1 at 6.5°1.49 at 11°0.0117
500,000101.9 at 5.5°1.53 at 13.25°0.0084
1 million120.7 at 4.75°1.61 at 16.5°0.0070
2 million136.9 at 4.5°1.71 at 17.5° No clear stall0.0061
5 million152.0 at 3.75°1.85 at 18.75° No clear stall0.0053
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources