Airfoil EPPLER 604 (e604)70 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

EPPLER 604 airfoil (e604)

EPPLER 604 is 18.8% thick at 41% chord, 3.3% camber at 41% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare EPPLER 604 with other airfoils

00.250.50.751 = chord
Shape of EPPLER 604, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness18.80% at 41.2% chord
Max camber3.33% at 41.2% chord
Trailing-edge gap0.00%
Points in source file70
Best L/D (XFOIL, Ncrit 9)185.1 at 3.75°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

70 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,0005.5 at 13.25°≥ 0.81 at 15.5° Stall not computed0.0377
100,00034.1 at 12.25°1.36 at 18°0.0319
150,000 Unreliable7.0 at 0°≥ 0.22 at 0° Stall not computed0.0200
200,00065.1 at 8.75°1.33 at 15.25° No clear stall0.0150
500,000 Doubtful106.6 at 7.25°1.42 at 17.75° No clear stall0.0090
1 million136.2 at 6.25°1.50 at 19.25° No clear stall0.0068
2 million162.9 at 5°≥ 1.57 at 17.75° Stall not computed0.0054
5 million185.1 at 3.75°≥ 1.68 at 20° Stall not reached0.0043
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00013.7 at 14.5°1.16 at 16.5°0.0355
100,00030.2 at 10.5°1.24 at 16.25° No clear stall0.0207
150,00053.1 at 7.5°1.29 at 16.5° No clear stall0.0156
200,00067.1 at 7°1.32 at 17.5° No clear stall0.0132
500,000101.9 at 6°1.41 at 18.75° No clear stall0.0087
1 million123.8 at 5.25°1.49 at 19° No clear stall0.0068
2 million140.3 at 4°1.57 at 19.75° No clear stall0.0056
5 million149.7 at 2.75°≥ 1.66 at 19.75° Stall not computed0.0046
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 150,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°.
  • Doubtful Use with care; see the reasons. Re 500,000, Ncrit 9: XFOIL's lift jumped far from the curve at single angles and straight back; those points were removed.
  • Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 100,000 (Ncrit 9); Re 50,000 (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources