Airfoil Eiffel 10 (Wright) - 1903 Wright Flyer34 pointsCoordinates: UIUCPolars: XFOIL 6.99
Eiffel 10 (Wright) - 1903 Wright Flyer airfoil
Eiffel 10 (Wright) - 1903 Wright Flyer is 2.7% thick at 0% chord, 6.2% camber at 40% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.
| Max thickness | 2.73% at 0.0% chord |
|---|---|
| Max camber | 6.22% at 40.0% chord |
| Trailing-edge gap | 0.64% |
| Points in source file | 34 |
| Best L/D (XFOIL, Ncrit 9) | 61.7 at 2.5°, Re 5 million |
Download for CAD made in your browser
Original file
Original coordinates (.dat, Selig format, unit chord)
34 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.
Polar charts XFOIL 6.99
Loading charts…
Performance by Reynolds number XFOIL, Ncrit 9
Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.
| Reynolds number | Best L/D | Max lift coefficient | Min drag coefficient |
|---|---|---|---|
| 50,000 | 28.4 at 3.25° | ≥ 1.32 at 20° Stall not reached | 0.0254 |
| 100,000 Unreliable | 31.7 at 3.5° | ≥ 1.01 at 3.75° Stall not computed | 0.0249 |
| 150,000 Unreliable | 16.5 at -0.5° | ≥ 0.48 at -0.5° Stall not computed | 0.0292 |
| 200,000 Unreliable | 14.2 at -1° | ≥ 0.42 at -1° Stall not computed | 0.0294 |
| 500,000 Unreliable | 36.1 at 2.75° | ≥ 0.94 at 3.25° Stall not computed | 0.0244 |
| 1 million Unreliable | 9.3 at -2° | 0.30 at -2° Too few points | 0.0321 |
| 5 million Unreliable | 61.7 at 2.5° | ≥ 1.29 at 7.75° Stall not computed | 0.0141 |
Same table for Ncrit 5
| Reynolds number | Best L/D | Max lift coefficient | Min drag coefficient |
|---|---|---|---|
| 50,000 Doubtful | 27.0 at 3.25° | ≥ 1.23 at 7.25° Stall not computed | 0.0295 |
| 100,000 Doubtful | 29.9 at 2.5° | ≥ 1.31 at 20° Stall not reached | 0.0253 |
| 150,000 Unreliable | 31.8 at 2.75° | ≥ 0.95 at 3.5° Stall not computed | 0.0238 |
| 200,000 Unreliable | 33.0 at 2.5° | ≥ 0.87 at 2.75° Stall not computed | 0.0232 |
| 500,000 Doubtful | 38.4 at 2.25° | ≥ 1.32 at 20° Stall not reached | 0.0206 |
| 1 million Unreliable | 96.2 at 2° | ≥ 1.01 at 4.25° Stall not computed | 0.0080 |
| 2 million Unreliable | 55.9 at 2.75° | ≥ 0.97 at 3.5° Stall not computed | 0.0148 |
| 5 million Doubtful | 67.9 at 3.5° | ≥ 1.34 at 7° Stall not computed | 0.0085 |
What the labels in the table mean
Labels in the table (“≥” means the true value may be higher):
- Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 150,000, Ncrit 5: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 200,000, Ncrit 5: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 1 million, Ncrit 5: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 2 million, Ncrit 5: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 100,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 150,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 200,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 500,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 1 million, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 5 million, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°.
- Doubtful Use with care; see the reasons. Re 50,000, Ncrit 5: XFOIL converged at fewer than three quarters of the angles from −5° to 15°; Re 100,000, Ncrit 5: XFOIL converged at fewer than three quarters of the angles from −5° to 15°; Re 500,000, Ncrit 5: XFOIL's lift jumped far from the curve at single angles and straight back; those points were removed; Re 5 million, Ncrit 5: XFOIL converged at fewer than three quarters of the angles from −5° to 15°.
- Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
- Stall not computed XFOIL stopped converging before stall was reached.
- Too few points Too few angles converged to judge the stall.
Where stall wasn't found, you can:
- treat max lift as “at least” the value shown;
- check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
- see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).
On this page XFOIL found stall at none of the computed Reynolds numbers.
Reliability and data quality
- No NeuralFoil estimate. NeuralFoil rates none of its results for this airfoil at 50% confidence or more, so its estimate is not shown.
- No shape problems found. The coordinate file passed all automatic checks.
About these predictions
- These are computer predictions. All polars on this page are XFOIL predictions, not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
Sources
- Coordinates: UIUC Airfoil Coordinates Database (file
eiffel10.dat, original name “Eiffel 10 (Wright) - 1903 Wright Flyer airfoil”). Cleaned by this site; see About the data. - Polars: XFOIL 6.99 by Mark Drela and Harold Youngren, run by this site. Settings are listed on About the data.