Airfoil GOE 10K29 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

GOE 10K airfoil

GOE 10K is 3.9% thick at 50% chord, 1.4% camber at 60% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare GOE 10K with other airfoils

Predictions unreliable. The source coordinates for this airfoil have only 29 points, which is too coarse for XFOIL. Lift, drag and L/D on this page may be badly wrong (for example unrealistic L/D spikes). Treat them as rough at best.

00.250.50.751 = chord
Shape of GOE 10K, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness3.85% at 50.0% chord
Max camber1.42% at 60.0% chord
Trailing-edge gap0.00%
Points in source file29
Best L/D (XFOIL, Ncrit 9)108.2 at 1°, Re 1 million (unreliable: coarse coordinates)

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

29 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Unreliable. coarse source coordinates; see the note above

Suspicious results. Suspicious drag at Re 5 million (Ncrit 9): The minimum drag is lower than even a perfectly smooth flat plate with fully laminar flow could achieve, so XFOIL's result can't be right. These polars are still shown, marked, so you can judge them yourself, but don't rely on them.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,000 Unreliable20.6 at 3.75°≥ 0.99 at 20° Stall not reached0.0146
100,000 Unreliable27.8 at 3.25°≥ 0.64 at 4.5° Stall not computed0.0107
150,000 Unreliable33.3 at 3°≥ 0.62 at 4.25° Stall not computed0.0090
200,000 Unreliable47.4 at 2.5°≥ 0.59 at 4° Stall not computed0.0081
500,000 Unreliable88.3 at 1.75°≥ 0.57 at 3.75° Stall not computed0.0050
1 million Unreliable108.2 at 1°≥ 0.56 at 3.5° Stall not computed0.0035
2 million Unreliable104.1 at 0.5°≥ 0.59 at 3.75° Stall not computed0.0025
5 million Unreliable Suspicious drag92.1 at 3°≥ 0.64 at 4° Stall not computed0.0004
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,000 Unreliable22.7 at 3.5°≥ 0.78 at 7° Stall not computed0.0146
100,000 Unreliable33.1 at 2.75°≥ 0.99 at 20° Stall not reached0.0108
150,000 Unreliable46.9 at 2.25°≥ 0.74 at 6° Stall not computed0.0091
200,000 Unreliable56.5 at 2°0.78 at 7.75°0.0076
500,000 Unreliable74.8 at 1°≥ 0.79 at 7.25° Stall not computed0.0048
1 million Unreliable60.9 at 3°≥ 0.78 at 7° Stall not computed0.0037
2 million Unreliable74.9 at 3.5°0.80 at 7.75°0.0048
5 million Unreliable96.9 at 4°≥ 0.95 at 19.25° Stall not computed0.0047
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Unreliable These XFOIL results are likely to be wrong; see the reasons. All polars: coarse source coordinates; Re 50,000, Ncrit 5: XFOIL converged at fewer than three quarters of the angles from −5° to 15°; Re 150,000, Ncrit 5: XFOIL converged at fewer than three quarters of the angles from −5° to 15°; Re 500,000, Ncrit 5: XFOIL converged at fewer than three quarters of the angles from −5° to 15°; Re 1 million, Ncrit 5: XFOIL converged at fewer than three quarters of the angles from −5° to 15°; Re 100,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 150,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 200,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 500,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 1 million, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 2 million, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 5 million, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°, Suspicious drag.
  • Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 200,000, 2 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources