Airfoil GOE 42333 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

GOE 423 airfoil

GOE 423 is 16.9% thick at 40% chord, 5.1% camber at 40% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare GOE 423 with other airfoils

00.250.50.751 = chord
Shape of GOE 423, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness16.94% at 39.6% chord
Max camber5.06% at 39.7% chord
Trailing-edge gap0.16%
Points in source file33
Best L/D (XFOIL, Ncrit 9)184.6 at 4.25°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

33 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00011.6 at 16°1.27 at 17.75°0.0563
100,000 Unreliable22.8 at 0.25°0.58 at 0.25°0.0243
150,00055.2 at 9.5°≥ 1.44 at 20° Stall not reached0.0152
200,00069.9 at 9.25°1.46 at 19.75° No clear stall0.0142
500,000105.7 at 7.5°≥ 1.42 at 20° Stall not reached0.0098
1 million133.2 at 6.5°≥ 1.41 at 20° Stall not reached0.0077
2 million160.9 at 5.5°≥ 1.52 at 20° Stall not reached0.0062
5 million184.6 at 4.25°≥ 1.71 at 20° Stall not reached0.0052
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00014.4 at 0.75°≥ 1.18 at 20° Stall not reached0.0301
100,00040.3 at 8°≥ 1.29 at 20° Stall not reached0.0182
150,00059.3 at 8.25°1.32 at 10°0.0153
200,00070.5 at 7.5°≥ 1.32 at 20° Stall not reached0.0137
500,000101.1 at 6.25°≥ 1.35 at 20° Stall not reached0.0097
1 million124.7 at 5.25°≥ 1.44 at 20° Stall not reached0.0078
2 million139.9 at 4.5°≥ 1.57 at 20° Stall not reached0.0067
5 million121.1 at 2.75°≥ 1.71 at 20° Stall not reached0.0066
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 100,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°.
  • Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 50,000, 100,000 (Ncrit 9); Re 150,000 (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources