Airfoil GOE 48133 pointsCoordinates: UIUCPolars: XFOIL 6.99

GOE 481 airfoil

GOE 481 is 13.6% thick at 10% chord, 8.8% camber at 39% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare GOE 481 with other airfoils

00.250.50.751 = chord
Shape of GOE 481, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness13.57% at 10.2% chord
Max camber8.81% at 39.4% chord
Trailing-edge gap0.00%
Points in source file33
Best L/D (XFOIL, Ncrit 9)94.2 at 10°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

33 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,0007.1 at 3.75°1.14 at 19.75° No clear stall0.0779
100,00042.5 at 9.25°1.74 at 14.5°0.0334
150,00050.0 at 9.25°1.74 at 18.5°0.0285
200,00075.4 at 7.5°1.67 at 18.25°0.0176
500,000 Unreliable31.2 at 1.5°≥ 0.85 at 1.5° Stall not computed0.0272
1 million Unreliable39.9 at 2°≥ 0.91 at 2° Stall not computed0.0227
2 million77.2 at 7.5°≥ 1.81 at 19.5° Stall not computed0.0179
5 million94.2 at 10°1.95 at 19.5° No clear stall0.0166
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00028.9 at 7.75°1.35 at 10.75°0.0403
100,00041.1 at 8.25°1.54 at 16.75°0.0315
150,00046.4 at 8.5°1.57 at 18° No clear stall0.0284
200,00069.0 at 7.5°1.58 at 16.75°0.0179
500,00058.3 at 8.5°1.65 at 16.5°0.0232
1 million63.8 at 9.75°≥ 1.71 at 15° Stall not computed0.0207
2 million75.7 at 10.5°1.80 at 19.5° No clear stall0.0189
5 million94.1 at 9.5°1.92 at 19° No clear stall0.0161
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 500,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 1 million, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 100,000, 150,000, 200,000 (Ncrit 9); Re 50,000, 100,000, 200,000, 500,000 (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions, not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.

What these checks mean

Sources