Airfoil GOE 50333 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

GOE 503 airfoil

GOE 503 is 15.6% thick at 30% chord, 7.0% camber at 40% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare GOE 503 with other airfoils

00.250.50.751 = chord
Shape of GOE 503, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness15.62% at 29.6% chord
Max camber6.98% at 39.6% chord
Trailing-edge gap0.00%
Points in source file33
Best L/D (XFOIL, Ncrit 9)170.8 at 6.25°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

33 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,0004.2 at 10.5°≥ 0.92 at 20° Stall not reached0.0686
100,000 Unreliable31.7 at 1.5°≥ 0.98 at 6.25° Stall not computed0.0264
150,00056.6 at 6.75°1.52 at 12.5°0.0181
200,00068.3 at 5°1.51 at 12.75°0.0157
500,00096.2 at 4.5°1.50 at 12.25°0.0104
1 million120.0 at 5°1.51 at 11.25°0.0086
2 million144.5 at 6.25°1.50 at 11.25°0.0075
5 million170.8 at 6.25°1.58 at 17.25° No clear stall0.0064
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,000 Unreliable15.8 at 2.25°≥ 0.65 at 4° Stall not computed0.0365
100,00046.4 at 5.5°1.32 at 12.5°0.0204
150,00059.3 at 5°1.39 at 12°0.0167
200,00067.0 at 5.25°1.41 at 12.75°0.0148
500,00091.4 at 4.75°1.43 at 11.5°0.0109
1 million109.7 at 5.25°1.44 at 11.75°0.0092
2 million126.5 at 6.5°1.46 at 16.75° No clear stall0.0079
5 million122.1 at 7°1.58 at 17.25° No clear stall0.0067
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Unreliable These XFOIL results are likely to be wrong; see the reasons. Re 50,000, Ncrit 5: XFOIL converged at fewer than half of the angles from −5° to 15°; Re 100,000, Ncrit 9: XFOIL converged at fewer than half of the angles from −5° to 15°.
  • Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 9); Re 100,000, 150,000, 200,000, 500,000, 1 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources