Airfoil LWK 80-150/K2597 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

LWK 80-150/K25 airfoil

LWK 80-150/K25 is 15.0% thick at 40% chord, symmetric (no camber). Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare LWK 80-150/K25 with other airfoils

00.250.50.751 = chord
Shape of LWK 80-150/K25, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness15.04% at 40.2% chord
Max camber0 (symmetric)
Trailing-edge gap0.00%
Points in source file97
Best L/D (XFOIL, Ncrit 9)90.6 at 11.5°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

97 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00028.0 at 5.75°0.95 at 8.5°0.0277
100,00038.2 at 5°1.00 at 9.5°0.0201
150,00036.6 at 5.5°1.01 at 11.75°0.0168
200,00038.6 at 5.5°1.03 at 13.5°0.0139
500,00052.3 at 4.5°1.17 at 16.5°0.0086
1 million59.3 at 3.5°1.31 at 17.25°0.0060
2 million68.9 at 8.75°1.49 at 18.25° No clear stall0.0044
5 million90.6 at 11.5°≥ 1.70 at 20° Stall not reached0.0035
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,000 Doubtful23.4 at 6°0.88 at 11.5°0.0280
100,00026.7 at 5.75°0.96 at 13.5°0.0184
150,00032.1 at 5°1.00 at 15°0.0147
200,00035.6 at 4.5°1.05 at 15.5°0.0125
500,00044.0 at 8.75°1.22 at 16.5°0.0078
1 million55.3 at 9°1.38 at 17.5°0.0057
2 million68.3 at 9.75°1.54 at 19.5° No clear stall0.0045
5 million88.9 at 11°≥ 1.68 at 19.75° Stall not computed0.0051
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Doubtful Use with care; see the reasons. Re 50,000, Ncrit 5: XFOIL's lift jumped far from the curve at single angles and straight back; those points were removed.
  • Stall not reached Lift was still rising at 20°, the end of the computed range. Treat the max lift shown as “at least”.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources