Airfoil S7012 8.75%81 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3Wind tunnel: UIUC LSAT, 9 tests

S7012 8.75% airfoil

S7012 8.75% is 8.8% thick at 28% chord, 2.0% camber at 34% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million. Wind-tunnel measurements from the UIUC Low-Speed Airfoil Tests.

Compare S7012 8.75% with other airfoils

00.250.50.751 = chord
Shape of S7012 8.75%, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness8.75% at 27.8% chord
Max camber2.02% at 34.5% chord
Trailing-edge gap0.00%
Points in source file81
Best L/D (XFOIL, Ncrit 9)119.9 at 3.75°, Re 2 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

81 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil + wind tunnel

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00033.8 at 7.25°1.10 at 9.5°0.0161
100,00051.9 at 6.5°1.14 at 10°0.0124
150,00062.7 at 6°1.16 at 10°0.0095
200,00070.4 at 5.75°≥ 1.17 at 10.25° Stall not computed0.0081
500,00093.8 at 4.75°1.23 at 10.75°0.0058
1 million109.1 at 4°1.29 at 11°0.0050
2 million119.9 at 3.75°1.37 at 11.75°0.0046
5 million119.1 at 3.75°1.51 at 13.25°0.0043
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00037.5 at 6.5°1.08 at 10.25°0.0162
100,00052.7 at 5.75°1.14 at 10.5°0.0112
150,00061.4 at 5.5°1.17 at 11°0.0095
200,00067.5 at 5.25°1.20 at 11°0.0085
500,00085.7 at 4.5°1.26 at 11.5°0.0066
1 million97.1 at 4°1.34 at 11.75°0.0059
2 million98.5 at 3.25°1.47 at 12.75°0.0055
5 million116.5 at 7.25°1.62 at 14°0.0054
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 50,000, 100,000, 150,000, 500,000, 1 million, 2 million, 5 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million, 5 million (Ncrit 5).

Wind-tunnel measurements

Wind-tunnel data: UIUC Low-Speed Airfoil Tests (LSAT). Produced under the UIUC Low-Speed Airfoil Tests (LSAT) program by Prof. Michael Selig and the UIUC Applied Aerodynamics Group, University of Illinois at Urbana-Champaign (UIUC Applied Aerodynamics Group). Free to use and share under the GNU General Public License; licence, copyright notice and the LSAT Manifesto. Never charged for.

  • Volume 1: M. S. Selig, J. J. Guglielmo, A. P. Broeren and P. Giguère, Summary of Low-Speed Airfoil Data, Volume 1, SoarTech Publications, 1995.
  • Volume 2: M. S. Selig, C. A. Lyon, P. Giguère, C. Ninham and J. J. Guglielmo, Summary of Low-Speed Airfoil Data, Volume 2, SoarTech Publications, 1996.
  • Volume 3: C. A. Lyon, A. P. Broeren, P. Giguère, A. Gopalarathnam and M. S. Selig, Summary of Low-Speed Airfoil Data, Volume 3, SoarTech Publications, 1998.
How the measurements are shown

S7012 8.75% was tested in the UIUC low-turbulence wind tunnel: 9 tests with 55 runs. In the charts above the measurements are markers, the XFOIL predictions lines. Lift and moment come from the force balance, drag from a wake rake in separate runs at their own angles, so the two kinds of run are shown separately and never combined. Each run is shown at its own measured Reynolds number; nothing is interpolated.

Wind tunnel vs XFOIL table: clean models only, where the measured Reynolds number is within 5% of one XFOIL was computed at. XFOIL: Ncrit 9. “≥” means the value may be higher (the measured lift run or the XFOIL polar ended before lift fell). Highest and lowest of the measured points, as printed in the source; no curve is fitted.

Wind tunnel vs XFOIL

ReMax lift, measured / XFOILMin drag, measured / XFOIL
100,000Volume 2, S7012 (B); measured Re: lift 100,600; drag 99,9001.087 / 1.143at 11.3° / 10°0.0118 / 0.0124measured at CL 0.06
100,000Volume 1, S7012 (B); measured Re: lift 102,000; drag 101,2001.083 / 1.143at 11.09° / 10°0.0102 / 0.0124measured at CL -0.05
150,000Volume 1, S7012 (B); measured Re: lift 152,600; drag 152,1001.107 / 1.162at 11.18° / 10°0.0095 / 0.0095measured at CL 0.23
200,000Volume 2, S7012 (B); measured Re: lift 201,000; drag 199,4001.121 / ≥ 1.173at 11.76° / 10.25°0.0089 / 0.0081measured at CL 0.27
200,000Volume 1, S7012 (B); measured Re: lift 203,200; drag 202,2001.090 / ≥ 1.173at 12.51° / 10.25°0.0075 / 0.0081measured at CL 0.19
All 9 tests and all Reynolds numbers
  • Volume 1, S7012 (B), clean: lift curves at Re 61,100, 102,000, 152,600, 203,200, 304,700; drag polars at Re 61,100, 101,200, 152,100, 202,200, 303,000; no moment data.
  • Volume 2, S7012 (B), clean: lift curves at Re 60,700, 100,600, 201,000, 301,400; drag polars at Re 60,100, 99,900, 199,400, 299,700; no moment data.
  • Volume 2, S7012 (B), flap 5° (clean: flap = 5 degs): lift curves at Re 60,500, 100,300, 200,500, 300,800; drag polars at Re 60,300, 99,900, 199,800, 299,900; no moment data.
  • Volume 2, S7012 (B), flap 10° (clean: flap = 10 degs): lift curves at Re 60,000, 100,100, 200,400, 300,500; drag polars at Re 59,500, 99,700, 199,600, 299,600; no moment data.
  • Volume 3, S7012 (B), tripped, flap 0° (flap = 0 degs; Zig-Zag trip type "C" @ u.s. x/c=2% & l.s. x/c=5% (h = 0.023")): lift curves at Re 100,600, 200,900, 302,000; drag polars at Re 100,500, 198,500, 199,600, 300,100.
  • Volume 3, S7012 (B), flap 15° (flap = 15 degs): lift curves at Re 99,800, 200,000.
  • Volume 3, S7012 (B), flap 20° (flap = 20 degs): lift curves at Re 99,900, 199,700.
  • Volume 3, S7012 (B), flap 25° (flap = 25 degs): lift curves at Re 100,000, 199,700.
  • Volume 3, S7012 (B), flap 2.5° (clean, flap = 2.5 degs): lift curves at Re 60,028, 99,947, 200,031, 300,168; drag polars at Re 59,938, 100,182, 200,048, 299,562.

Reliability and data quality

About these predictions
  • Lines are computer predictions, markers are measurements. The polar lines and the performance table are XFOIL predictions (dashed lines: NeuralFoil estimates). XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. The markers are wind-tunnel measurements from the UIUC Low-Speed Airfoil Tests; see Wind-tunnel measurements below.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources