Airfoil SIKORSKY SC1094 R8145 pointsCoordinates: UIUCPolars: XFOIL 6.99Estimates: NeuralFoil 0.3.3

SIKORSKY SC1094 R8 airfoil

SIKORSKY SC1094 R8 is 9.4% thick at 28% chord, 2.1% camber at 22% chord. Polars were computed with XFOIL 6.99 at Reynolds numbers from 50,000 to 5 million.

Compare SIKORSKY SC1094 R8 with other airfoils

00.250.50.751 = chord
Shape of SIKORSKY SC1094 R8, drawn to scale; dashed line: chord. Coordinates: UIUC Airfoil Coordinates Database.
Geometry
Max thickness9.40% at 27.6% chord
Max camber2.12% at 21.7% chord
Trailing-edge gap0.34%
Points in source file145
Best L/D (XFOIL, Ncrit 9)140.4 at 9.75°, Re 5 million

Download for CAD made in your browser

Original file

Original coordinates (.dat, Selig format, unit chord)

145 points, chord 1. Opens in XFOIL, XFLR5 and many CAD add-ins.

Polar charts XFOIL 6.99 + NeuralFoil

Loading charts…

Performance by Reynolds number XFOIL, Ncrit 9

Method: XFOIL 6.99, computed by this site. Mach 0. Angles of attack in degrees.

Performance by Re · XFOIL · Ncrit 9
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,000 Doubtful24.5 at 2.75°≥ 0.91 at 7.5° Stall not computed0.0181
100,00033.7 at 4.75°1.08 at 9.25°0.0125
150,00040.3 at 5.25°1.21 at 10.75°0.0100
200,00045.5 at 6°1.28 at 11.5°0.0088
500,00067.9 at 7°1.61 at 16°0.0066
1 million88.5 at 8.75°1.85 at 18.5°0.0066
2 million111.0 at 9.25°1.96 at 17.75°0.0063
5 million140.4 at 9.75°2.03 at 19° No clear stall0.0058
Same table for Ncrit 5
Performance by Re · XFOIL · Ncrit 5
Reynolds numberBest L/DMax lift coefficientMin drag coefficient
50,00027.2 at 6°1.10 at 10°0.0175
100,00037.6 at 6.25°1.29 at 12°0.0121
150,00045.1 at 7°1.39 at 12.75°0.0101
200,00050.8 at 7.5°1.46 at 14.25°0.0093
500,00072.8 at 8.5°1.67 at 17°0.0083
1 million91.9 at 9.25°1.84 at 17.75°0.0077
2 million112.3 at 10°1.89 at 18°0.0069
5 million139.7 at 10.5°1.97 at 18.75° No clear stall0.0063
What the labels in the table mean

Labels in the table (“≥” means the true value may be higher):

  • Doubtful Use with care; see the reasons. Re 50,000, Ncrit 9: XFOIL converged at fewer than three quarters of the angles from −5° to 15°.
  • No clear stall Lift levels off but doesn't fall within the computed range (up to 20°).
  • Stall not computed XFOIL stopped converging before stall was reached.

Where stall wasn't found, you can:

  • treat max lift as “at least” the value shown;
  • check the same airfoil at a nearby Reynolds number or Ncrit where stall was found;
  • see the wind-tunnel measurements, for the airfoils that have them (marked “wind tunnel” in the airfoil list).

On this page stall was found at Re 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 9); Re 50,000, 100,000, 150,000, 200,000, 500,000, 1 million, 2 million (Ncrit 5).

Reliability and data quality

About these predictions
  • These are computer predictions. All polars on this page are XFOIL predictions (dashed lines: NeuralFoil estimates), not wind-tunnel measurements. XFOIL tends to overpredict maximum lift, especially at low Reynolds numbers. No wind-tunnel measurements of this airfoil are available here.
  • NeuralFoil estimates. A switch above the charts adds NeuralFoil estimates as dashed lines. NeuralFoil 0.3.3 is a neural network trained on XFOIL results. It is quick and never fails to converge, but because it learned from XFOIL it shares XFOIL's errors, so it is a second estimate, not a check on XFOIL. Points it rates below 50% confidence (mostly past stall) are left out.

What these checks mean

Sources